Breathe Easier, Save Energy:The Hidden Benefits of Cold-Water Humidification

Training Manual
Quick Links
Recent Posts

HVAC logic improvements

APS has developed many unique HVAC logic circuits: improving comfort and reducing energy consumption. The reductions caused the avoidance of over 60,000 person-years of GHG emissions with a three-person crew.

Read More »

Letter of support

David Strain’s invention demonstrated an efficiency advantage greater than 15°/o favoring the diamondshaped
actuator over a conventional actuator.

Read More »

A great asset to DDSB

David has been our primary Controls Contractor for last 25 years. We are always surprised that even today he comes up with new and innovative designs.

Read More »

A climate in crisis. There is a workable solution

APS Controls introduces an internationally patented invention capable of reducing global fossil fuel consumption by over 33%, which could save $832 billion annually. Despite its potential, the invention faces rejection from governments, universities, and environmental organizations without substantive technical critique.

Read More »

When Physics Gets Puzzling

The Energy Enigma That’s Got Scientists Scratching Their Heads

What happens when a simple invention challenges one of physics’ most famous equations? Spoiler alert: Einstein might need to make room at the table.

Read More »
Questions?

Simple Ways to Save Energy with Humidity Control

Controlling humidity isn’t just about comfort—it also helps reduce the spread of viruses and bacteria. While most standard humidifiers use a lot of energy, cold-water spray systems can actually help save on heating costs.

The Misunderstanding About Safety

Many buildings have replaced cold-water spray humidifiers with steam humidifiers because of concerns about Legionnaires’ disease. However, according to the CDC, this isn’t actually a risk—the bacteria can’t grow in cold water below 68°F (20°C). These systems are safe since humidification is only needed in cold weather when water and air temperatures are well below this threshold.

The Problem with Traditional Setups

Most cold-water spray systems were installed in a way that forced the building’s heating system to compensate for the cooling effect of water evaporation. This happened because the temperature sensors were placed in the wrong location.

A Simple Fix with Big Results

With just a few hours of work and minimal materials, we made a small control change at the Etobicoke Board of Education building:

  • Captured heat from the exhaust air
  • Maintained a comfortable supply of air temperatures
  • Reduced gas consumption by over 50%

What Went Wrong

Unfortunately, a humidifier salesperson later convinced the staff to switch to steam humidification. This not only eliminated the energy savings but also increased electricity use. When the building’s heating bills shot back up, we implemented a more complex solution that ultimately reduced gas consumption by 60% compared to the original setup.

Key Points About Cold-Water Humidification Systems

  • Low indoor humidity promotes virus and bacterial growth, increasing infections and discomfort (ASHRAE*)
  • Cold-water humidity spray systems have been unnecessarily abandoned due to misconceptions about Legionnaires’ Disease risk (contradicted by CDC data)
  • Traditional installations placed temperature sensors in the wrong location, missing energy-saving opportunities
  • Relocating sensing points for mixing dampers from upstream to downstream of humidity sprays enables significant energy reclamation (52.6% reduction at Etobicoke Board of Education)
  • Proper sequencing of control operations is essential for system efficiency
  • Regular maintenance of all humidifiers remains critical for performance and safety
  • Automatic draining based on water temperature and regular flushing should be implemented for optimal operation


*Note: American society of Heating, Refrigerating, and Air-Conditioning Professionals